Replay a delivery (Run again)
Run again re-sends a failed (or successful) delivery from the log. It re-renders the payload template against the current Jira state and produces a new log row linked back to the original.
This is the manual retry mechanism. Webhooks Pro does not auto-retry — see Retries and auto-disable. Replay is in your hands, and that's deliberate.
Single-row replay
Two places to click Run again:
The button in the Action column of the row.
The same button inside the row's expanded detail panel.
A confirmation prompt? — no. Replay is one click. Unsafe? — no, because:
The original recipient is unchanged (same URL, same headers).
The new attempt is logged separately, not overwriting the original.
You can replay the replay if it also fails.
A warning triangle next to the button calls out failures that are likely permanent (e.g. 401 Unauthorized). Replaying without fixing the cause is just going to fail again — but you can if you want.
Bulk replay
Tick the checkboxes on the rows you want to retry. The header checkbox toggles all eligible rows on the current page.
The bulk action bar appears at the top of the table with the selected count.
Click Run again in the bulk bar.
Webhooks Pro replays each selection in sequence and refreshes the view.
Only rows eligible for replay can be selected. The header checkbox respects this — it only ticks eligible rows. See Eligibility below.
What "Run again" actually does
Two important consequences:
The replayed payload reflects the issue as it is NOW, not the snapshot from the original delivery. If the issue summary changed since the original event, the replay will carry the new summary. This matters when you replay long after the failure.
Egress approval and licence gates apply at replay time. A replay can be skipped (Skipped lozenge) if the licence flipped between original and replay.
Eligibility — when does the button appear?
The Run again button is shown only when the row's HTTP status is in the retry ranges configured on Tenant settings → Webhooks → Run again button:
Range | Default |
|---|---|
2xx Success | ✅ on |
3xx Redirect | ✅ on |
4xx Client Error | ✅ on |
5xx Server Error | ✅ on |
Network Error | ✅ on |
Other / Custom | ✅ on |
Defaults: all categories are eligible. Toggle ranges off if your workflow says they shouldn't be replayed (e.g., you don't want admins replaying 4xx because those are usually config issues that need fixing first).
Already-replayed rows do not show the button — you click Run again on the latest replay child instead, not the original. The chain is visible: latest is the freshest attempt.
Skipped rows (licence-blocked) don't show the button — there's nothing to replay, the original was never sent.
Replay grouping in the UI
The replay is saved as a new row with sourceLogId pointing back to the original. The UI shows:
Replays indented under their parent.
A blue left border on replay rows.
A ↳ glyph in the checkbox column.
Both the parent and the child appear on the same page so you see the full history at a glance.
Enable Hide replayed (top of the page) to collapse each chain and only see the freshest attempt — useful when scanning a long log.
When to replay vs. when to fix first
Symptom | Replay first or fix first? |
|---|---|
503 Service Unavailable, looks like a transient receiver blip | Replay. The receiver was probably overloaded for a moment. |
Timeout (Network Error) on a normally-fast endpoint | Replay. Likely a transient network event. |
401 Unauthorized | Fix. Your auth header is wrong. Update the webhook, then replay. |
404 Not Found | Fix. Either the URL is wrong or the receiver moved. Update the URL, then replay. |
400 Bad Request with a specific error message | Fix. Adjust your payload template based on the receiver's complaint, then replay. |
Network Error consistently, never works | Fix egress approval first. See Status code 0 and network errors. |
Skipped (licence-blocked) | Fix licence. Renew, then replay. |
The warning triangle on the Action button surfaces the "fix first" cases automatically.
Replay during a backfill
If you have hundreds of failed deliveries you want to retry after fixing the receiver:
Filter to Status = 4xx, 5xx, Network Error + the date range of the outage.
Tick the header checkbox to select all eligible rows on the page.
Click Run again in the bulk bar.
Page through and repeat.
Each batch fires sequentially. If the receiver has a rate limit, consider replaying smaller batches with a pause between them (manual — Webhooks Pro doesn't throttle replay rate per group).
Replays don't reset the auto-disable counter
A successful replay counts as a success in the per-webhook counter — so if your webhook was on the verge of auto-disable from consecutive failures, a successful replay does reset the counter to 0.
A failed replay counts as a failure — and can push the counter over the threshold. Be intentional with bulk replays of failed rows on a webhook that's near auto-disable; mass-replaying a hundred 5xx rows can flip the webhook to disabled.
If your webhook is already auto-disabled, replays still go through — the disable only blocks new events, not replays of existing log rows.
Common mistakes
Mistake | Effect | Fix |
|---|---|---|
Replay 401 / 403 without fixing the auth header | Replay fails the same way; counter ticks toward auto-disable | Fix auth on the webhook form first. |
Bulk-replay an outage during the outage | Replays also fail, counter spikes | Wait until the receiver is verified healthy. |
Expect the replay to use the snapshot at original-delivery time | Replay uses current Jira state | Document the discrepancy if you replay long-after-the-fact deliveries. |
Replay a row that was Skipped | Button doesn't appear | Renew licence first. |
Related
Webhook logs — the hub.
Inspect a delivery — read the row before you replay.
Filter and search logs — find the rows worth replaying.
Retries and auto-disable — why replay is manual.
Tenant settings → Run-again button ranges.